The Disconnect power to the pump and wait until the keypad LEDs have all turned off. E06 Error Code 2 More Confused Error Codes Of Pentair Heater 1. It is probably a built-in basket for debris and empty it when it becomes full. WARNING: Any troubleshooting that involves electrical work is dangerous, and should be performed by a professional pool heater repair tech. I looked down and viewed my mistake of allowing part of the plastic sheet to cover the pool motor fan intake. It is probably a built-in failsafe so that the pump doesnt overheat and become damaged. This is because, after 60 seconds of mistake, the heater will enter lockout mode. Any suggestions? If the error has not cleared then proper troubleshooting will be required. You need to test each of the components to see if they are the culprit. Hopefully will warm up soon and I can reset. Remove screen from bottom of pump and make sure nothing is preventing the impeller from moving freely. Using its control panel, you can easily set and reset the 4 selectable preset speeds or set the pump speed to run at a certain speed. : https://www.swimmingpoollearning.com/swimming-pool-care-ebook, https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzP, Swimming Pool Tips, Reviews & How To Video Index (List) Alphabetical order. If the issue code remains after trying all of these steps, you should seek expert assistance. Get exclusive pool heating tips, time-saving pool care hacks, and first-access to members-only news and special offers. screwdriver. At this point, reconnect power to the pump. We are a registered 501(c)3 non-profit that is funded by user donations. Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable. That is the overcurrent fault code. COPYRIGHT 2023. It was never meant to be public, but looks like others are looking at this so i'll try to make it useful.I was having a problem with my pump where you could hear it reset itself for no reason. New Pentair pump giving error codes 0002 and 000F Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. The error code E03 means that the thermal fuse of the STA-RITE is open. But like anything electronic running from software, error codes will appear from time to time.If you see that your SuperFlo VS is not running as scheduled, flip open the top and see if there is an error code of some kind. Clogged exhaust or air vents, a sooted exchanger, inadequate water flow, or a defective stack flue sensor are all possible reasons for this mistake. In this section, we will look at what each error code means and what are the simple solutions for these errors. Pool pump choice: Jandy 1.85HP VS Pump vs. Pentair Superflo VST 2.2, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. For a better experience, please enable JavaScript in your browser before proceeding. start/stop button to start up the pump. I tested that ground circuit from my breaker box and was getting very odd readings. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. I got a new one from Pentair. The Hole in One Basket: Connect a Cleaner at the Please consider. The Number One Source for All of Your Pool Care Needs. The Pentair SuperFlo Variable Speed pump is a great If the above does not work you will need to have the pump and connections tested with a multimeter to see where the short is. When your heaters ignition control module fails to fire up the heater, this error code will be on display. : https://youtu.be/huAt9BXLu9ISuperFlo VS Playlist: https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzPVisit my Website: http://www.swimmingpoollearning.com/eBook: https://www.swimmingpoollearning.com/swimming-pool-care-ebookYouTube Video Index: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-reviews-how-to-video.html A list of all of my videos.Follow Me:Google +: https://plus.google.com/+MrDgvb1/postsBlogger: http://poolmandave.blogspot.com/ Facebook: https://www.facebook.com/pages/Youtube-Mrdgvb1/381257741926763?ref=hl Twitter: https://twitter.com/Mrdgvb1Join me on Patreon: https://www.patreon.com/poolguycoachingPodcast: http://www.buzzsprout.com/110832Podcast Website: https://www.thepoolguypodcastshow.com/Coaching Site: https://poolguycoaching.com/Shop INYOPools: www.inyopools.com?utm_source=youtube\u0026utm_medium=swimming-pool-tips brand new pentair vs gives out code EOFF ,then shuts off . Freeze protection is provided by selecting YES at the ON WITH FREEZE A malfunctioning thermistor, poor or damaged wiring, a bad control board, or a failed temperature sensor are all possible causes. Is this normal? The AFS being open will cause this error message to pop on your screen. . The Err 0002 can also indicate a wire is loose in the Press J to jump to the feed. It does this at all speeds not just one on setting. After power is reconnected if one of these errors continues to reappear, the drive may need service. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. Fill the pump up with water and put the lid back on. It means that your heater is getting too hot and the high limit switch turns off the heater for safety. It would self prime in about 1 minute and everything was happy. JavaScript is disabled. This is totally a manufacturing problem on pentair's end. Your heaters front panel will stop working when this error occurs. You must check that the rate of water flow is within the range specified and that the water temperature does not exceed 140F to correct this error. Insufficient water flow is usually caused by a dirty filter. If you have a suction side cleaner not need to do any other troubleshooting unless the Err code does not clear after 12 Pentair Heater Error Codes, Their Meanings & Solutions 1. pump or a poor connection. Press the down or up button to decrease or increase the pump speed. Otherwise, after youve fixed the blower, youll have to reset the heater. Other reasons why the heater is not turning on include: Faulty igniter The defective ignition control module Bad control fuse its quick and easy way. For a better experience, please enable JavaScript in your browser before proceeding. Any new postings here are unlikely to be seen or responded to by other members. Benefits of a Pentair Variable Speed Pool Pump Higher Performance Consistent flow control for the highest energy saving and ultimate system performance. This is caused by insufficient water flow through the heater. It Hi, I have an error code on my Pentair variable speed pump. Variable speed pumps move water more efficiently at lower speeds, saving money and energy. The buttons on your heaters front panel buttons will be disabled during this malfunction. Its possible that theres air in the pipes. Mine ended up being a faulty control board. If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. Pentair pool heater troubleshooting guide, Pentair Heater Error Codes [Reasons + Solutions], Water Flow Rates For Different Pentair Models, 2 More Confused Error Codes Of Pentair Heater. If your igniter doesnt spark, it is faulty and needs replacement. getting clogged and the pump is unable to prime. So, if you have an older pool on a single 110V breaker the SuperFlo VS pump is pretty much the only Variable Speed Pump that you can install. Spin it completely around several times to make sure the blockage is cleared. Does anyone know why it would cut off like this? The freon in your pool heating system should last roughly 15 years, or as long as the device itself. this may free the blockage. Pentair heaters sometimes display codes R13 and R14. codes will appear from time to time. . If this happens, your safety circuit components, membrane pad, or control board may be damaged. This bond opens due to excessive heat. The heat pumphas locked due to five HP(high-pressure) faults during one call for heating or cooling. I got that a few times the other day while backwashing but the pump Would kick on a second or two later. Edward in TX 22.4K subscribers Subscribe 35K views 2 years ago #capacitor #poolpump My Pentair pool. Doing this may free the blockage. Followed instructions on page 14 of manual. How long does a Pentair pool heater take to heat a pool? ERR SFS signifies the stack flue sensor on your heater has reached a temperature of more than 480F. Very low pH and alkalinity levels over several years can strip the copper from a heat exchanger and wear the tube walls paper thin.Saltwater pools can also develop corrosion around fin welds, which could . ERR IGN Error Code 5. The pump is brand new and never used. Pentair Pool Pump Not Working? The screen will display an error code as Err and then display a number. Make sure that your variable pump is on this means ensuring that the green power LED is turned on. If the blockage was removed the screen will no longer show the Err 0002 code. Create an account to follow your favorite communities and start taking part in conversations. In some cases, you may need to replace your current pump with a new one entirely. To fix the error codes E01 and E126 with your Pentair pool heater, very first, inspect whether the thermistor is working. read more Poolservice123 CPO, CPI, CBP Associate Degree 1,028 satisfied customers I have a Pentair SuperFlo VST pump motor that I need to 21 Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. I have a pentair superflo vst pump installed about 6 months ago has been working great but now has a code Err oooF checked power and no problem there has proper voltage I think it is the drive you can Quieter These pumps barely make a whisper. If you have a suction side cleaner connected to the pool, make sure you are using an in-line leaf canister. It is being practiced by thousands of pool owners just like you. I have not had the error since and the drive has been working great. Is that an overcurrent fault code? clear the impeller jam the pump will start up and run like normal. With extensive experience in pool repair and manufacturing, I only saw it that day, didnt do anything about it and havent had a problem since. Energy & Cost Savings Slow and steady wins the race. These codes are a great way to do a simple diagnostic to see what issues your pump is having. I can make it work if I take an Allen wrench and manually spin the impeller for a few rotations. So when the E03 error code comes up, you can conclude that your heater is burning. Note: Only a member of this blog may post a comment. I am new to the Forum but have loved the advice and guidance I have received through here for the last two years. Thanks --Jason I set up a gopro for hours and finally caught it giving and error 0021.Pentair was an absolute disaster to deal with but i was finally able to get them to send me a new drive. You should not need to do any other troubleshooting unless the Err code does not clear after one or two resets. Pentair IntelliFlo Variable Speed Pump is one of the best pumps that you can use for your pool, cleaner, waterfall, spa, and other water uses. Press J to jump to the feed. Impeller is stuck or jammed with debris. You can turn the impeller by using a 1/4 allen wrench at the back in the fan. These error code explanations will give you some guidance for resolving the most common Pentair pool heater problems: NOTE: Any troubleshooting that involves electrical work, or opening the heat pump, should be done by a professional, What it means: temperature sensordetecting water above 107 degrees, What it means: temperature sensordetecting water below 40 degrees, What it means:the units low-pressure switch senses that water flow is open or low, What it means: remote inputs of Pool AND Spa are being triggered, What it means: water thermistor circuit is shorted, What it means: water thermistor circuit isopen/receiving constant power, What it means: defrostthermistor circuit isshorted, What it means: defrostthermistoris open; power is being interrupted, What it means:the 24 VAC supply voltage to the heat pump circuit board is low. Check out the chart below to see which range is best for your model. You must log in or register to reply here. Pentair pool heater error code E05 indicates that the stack flue sensor is open, as the exhaust temperature was determined to be above 176F. But if the water temperature is cool enough but the error message is still there, it means that there is something wrong with the high-limit switch. When your pressure switch is stuck open, you will find the Pentair pool heater error code PS on your heater display. In ERR PS, the PS stands for the pressure switch. If you get really fine particle debris, you can insert a filter sock or filter saver in the skimmer basket to trap the smaller particle debris that can fit through the pump basket and enter the impeller. The FLO code indicates that the water flow to your heat pump has been halted by the filter pump. Hello , This is an inactive thread. Once the impeller spins freely the blockage has been cleared. The second method is to use a Allen Wrench and If you had an installer do it, and you still have a warranty, i would call them out (because it is free) and tell them about this repair and see what they say. I put my voltage meter on the pump's load 1 and load two and it only read 118V. Read our article on Pentair ignition failure to learn more. If you see that your SuperFlo VS is not running as Call the installer and have them check it out or have them get a warranty tech from Pentair to fix it. ERR PS Error Code Water Flow Rates For Different Pentair Models 2. This is especially useful in the afternoon when your houses cooling needs are highest and its cooling efficiency is lowest. Run the filter pump for a few minutes after turning on the heater for the first time or after a long period of time off to clear all air from the system. Dolphin Triton PS Plus Automatic Pool Cleaner Review, The Best Pool Cover for Winter, Inground Above Pools. There is either a white or yellow wire connected directly to the back of the board. This means the motor was getting too hot. I went and checked the pumped and the display screen said "Err 0021". So, if you have an older pool You are using an out of date browser. Ensure adequate flow rate of water. Press question mark to learn the rest of the keyboard shortcuts. Looking that up I found that this indicated an "Absolute Diode Bridge temperature limit exceeded". The temperature sensor on your Pentair pool heater is open, as indicated by both the Pentair pool heater error codes E01 and E126. jammed in there. choice for a Variable Speed Pump. All rights reserved. RESOLUTION Remove side access panel, two screws. When the temperature of the water going through the heat exchanger for the second time exceeds 140F, the Pentair pool heater error code AGS occurs. If the blockage was removed the screen Effect 20 RPM increments by pressing and holding the down/up button to steadily decrease or increase the pump speed. What exactly should I be looking for? The ERR HLS code means that your heaters high-limit switch is stuck open. Then turn it on and it works fine. What would be the cause of that? Clean the pool filter. I originally. I've had an occasional bad drive out of the box. Be sure to contact us through our website for our variety of services.. most common one is the Err 0002 and it is usually caused by the impeller scheduled, flip open the top and see if there is an error code of some kind. When a problem is diagnosed as a consequence of this examination, you must address the problem. Anti-freezing: When active, the motor will run at 1000 rpm for 60 minutes. Here's how, Shut off the whole system At this point you may want to call out a pool The HLS may need replacement. external slip) You should be able to press the start/stop button to start up the pump. See page 14 Pump Disassembly for instructions for disassembling the pump. Check the fuel supply, the heat regulator, and any orifice blockages again. Riptide Vacuum System Steering Knuckle Upgrade! And in that case, the common error codes with your Pentair MasterTemp are ERR PS, ERR HLS, ERR AFS, ERR IGN, ERR AGS, ERR SFS, E01, E05, and E06. Solution: As the thermal fuse has gone bad, you have to replace it. It could be a bad drive but that is not common. Who Makes the Best Pool Equipment -Pentair, Hayward, Jandy or Off Brands? To prevent the impeller from being clogged check your skimmer The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. The Err 0002 Your information will *never* be shared or sold to a 3rd party. To get rid of this error message, youll need to make sure theres enough water flowing. All looked okay. Check on the units wiring to ensure that isnt the problem. When you dont use a sun cover, the heat that your heat pump puts into the pool is lost into the air. Want to lower your pool heating bills and make pool care easy? So, if you. if you have problem to your pool pump pentair. The Err 0002 will prevent the pump from running until you clear the blockage.So, if the pump is on, hit the start/stop button to turn it off. It means that the SFS has shorted. Seek professional heat pump repair, Outside temperatures are too low to operate, Have pool heater tech check if the switch needs to be replaced, Check for additional error codes that are listed in this post. If necessary, clean the heat exchanger. Go for the same solution as we have suggested for the E05 error code. Power off the unit and restart. When the pump is running it seems to run for 20 - 30 minutes then it cuts off for 15 - 20 seconds then comes back on. service professional to trouble shoot the pump. It says "Err" and then "0002" and won't turn on. It will then begin to go into the priming mode and then start up. Otherwise, the temperature sensor may be faulty. Save the speed you have chosen by pressing and holding the speed buttons to allocate that speed. The method I always use is to remove the pump lid and pump basket, then I spin the impeller with a screwdriver. This was typically happening in quick clean mode. Heat pumps do require maintenance twice a year. Maybe i will take the drive apart and add some pictures to the end of the video if i get motivated. Heat pump troubleshooting guide for Pentair pool heaters. The manual states that I should disassemble the pump and check the impeller and seal plate. Ooops. Do you need a high pressure pump for spa jets and water features? through and into the pump impeller. At this point you may want to call out a pool service professional to trouble shoot the pump. I do have pine needles that make it through the basket occasionally, so wondering if those are getting caught. *17,16, 02, 08, 04, 06, 09, 0A Internal Errors: These errors can occur based on operating conditions and the UL 60730 required self-diagnostic safety software. A repository of Pentair stakeholder and customer information at your fingertips including white papers, case studies and product manuals, etc. You should Views: 44 Report Jimrahbe Mod Squad TFP Expert LifeTime Supporter Jul 7, 2014 28,282 Bedford, TX The time it takes a heat pump to heat a pool is determined by a few factors. If purchased online will only receive a sixty-day limited warranty. I also use the screwdriver to scrape away any debris that may be jammed in there. The Pentair heater error codes displayed in your heater display tell you that you need to address specific issues with your heater. Please consider. Decoding the errors on your pump 21 - Communication link between HMI and motor control has been lost Speed 1 LED/button will select the first speed which is 750 RPM. Pentair Minimax NT STD ERR message Postby Guru Thu 18 Feb, 2010 14:40 9 times out of 10 the "ERR" code is caused by a bad thermistor (temp sensor). Pentair heater error code E06 is another error code related to the stack flue sensor. one or two resets. Let me know what you find. Replace it. A heat pump, on the other hand, often heats a pool by 20 degrees Fahrenheit after 24 to 72 hours. SFS stands for stack flue sensor. Then reading how to fix the Pentair heater error code R13 guide will help you a lot. It is controlled by an Easytouch and also has an Intelliclor salt system. Press question mark to learn the rest of the keyboard shortcuts. Call Us Nationwide: 1-800-741-9956 West:213-291-9276Southwest:480-719-4511 Midwest:312-229-0026 Northeast:631-223-7175 Southeast:239-247-5878 Trustpilot Menu Browse Heaters Back In that case, you can read our comprehensive guide on how to deal with Pentair heater error code R14. You are using an out of date browser. Gently turn it back in forth until the Only active in Filter and Manual modes. View the list of TradeGrade Products. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. It may take a bit of effort. is connected at the skimmer you may want to try the after-market Hole in One Basket I took mine apart (quite a pain) and there was nothing of interest there. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. Press the button of the speed you have assigned to ensure that your unit runs with that speed. If you get really fine particle debris, you can insert a The cooling effectiveness of either a heat pump or an air conditioner can be improved by shading the exterior unit. I had pump running 24/7 due to freeze. When you notice the Pentair heater error code R13, you dont need to do anything because its merely a part of the startup routine. (The fan and impeller are on the same axle.) Yes, it is necessary. When you wire up this pump you basically have your two hot wires coming from the breaker, and you have a ground that screws to the case of the drive. Read our troubleshooting guide to figure out how to fix a faulty Pentair blower. ERR- ERROR Code ERR indicates a "hard lockout" error which means you will need to reset the power of the heater through the switch on the bottom of the electrical junction box once the errors are fixed. Improper voltage or supply voltage. If your mini-split has a leak, a professional may be required to add refrigerant after the repairs are completed. 0F Absolute AC Under-Voltage Detected: This indicates that the supply voltage has dropped below the operating range of 99v. Speed Pump that you can install. cleared. What it means:refrigerant systems high-pressure switch is open, What it means:refrigerant systems low-pressure switch is open, What it means:5 faults have occurred within the heat pumps last cycle, Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000, Hours Mon-Fri: 8am 7pm Saturday: 9am 5pm Sunday: By Appointment, Service Areas Anywhere in the United States and throughout Florida.Orlando, Longwood, Miami, Tampa Bay, Jacksonville, St Cloud, Tallahassee, Daytona Beach, Davenport, Windermere, Clearwater, and the rest of North, South, and Central Florida. Remove any obstructions. I then did each line separately and found out one wasn't connected to the double pull GFI breaker correctly. Disclaimer, if you chose to do this it is at your own risk. If Code ERR is shown on the LED display at any time, turn the heater off at the power switch and then turn the heater back on. The pump ran fine yesterday. POOL OPERATORS AND OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS IN THE OWNER'S MANUAL BEFORE USING THIS PUMP. Now go to the breaker and turn the pump breaker off And does anyone have a possible idea as to what is happeneing? But more than likely when you clear the impeller jam the pump will start up and run like normal. There are a number of reasons why your blower can stop working. The water temperature needs to fall below 135F for the high limit switch to close again and your heater to start working again. SuperFlo Pool Pump by Pentair Aquatic Systems is a direct replacement for the Hayward Super Pump Extremely quiet operation; Unionized fittings included (1-1/2 in. The problem can be a malfunctioning blower fan or blockage of the fan air. 001a Error code on Pentair Superflo VS pump. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. At ePoolSupply and poolinfloor.com, we know our pool parts. Make sure to see if there is any dirt blocking the air vents or exhaust and ensure all of these items are working. Error Code E06: Stack Flue Sensor Is Shorted 3. will prevent the pump from running until you clear the blockage. 02 -Absolute Phase current limit exceeded*, 08 -Absolute Diode Bridge temperature limit exceeded*, 04 -Absolute Power Module temperature limit exceeded*, 06 -Absolute Power Factor Correction (PFC) temperature limit exceeded*. Error 0021 on Pentair Superflo VS 303Michael Jul 4, 2022 Pumps, Filters, and Plumbing 5 Pumps, Filters, and Plumbing Jul 27, 2022 303Michael Any hacks for a remote controlled Black and Decker Pool yet? Pentair X-Flow Xpert Web App; Aurora . voltage and be used at 120V as well as at 230V. You will get much more visibility by. I installed a new Superflo VS pump on my 16x36 inground pool. Possible causes include incorrect wiring, dirt and debris obstruction, a lack of power supply, a defective ignition control module, and so on. Nothing made it work so I bought a new one. priming mode and then start up. It simply means that your heaters system is being examined for possible problems. Effect 10 RPM increments by pressing and quickly releasing the down/up to decrease or release the pump speed. What could be the issue here? I originally posted it only so the folks at pentair could see it and totally forgot about it. Error Code ERR HLS: Hi Temperature Switch Is Open Go Back. You would think the ground screw would be conductive enough but it turns out that green coating has a ton of resistance and prevents you from getting a good ground.So I carefully removed the powder coating under that ground screw and reconnected everything and my resistance went to 0 ohm on the ground line indicating a perfect path to ground.
Larry Miller Accident, Manchester Giants Player Salary, Oukaning Ceiling Fan Installation Instructions, Blairmount Public School Principal Stood Down, Port Protection, Gary Muehlberger Dog, Articles P
Larry Miller Accident, Manchester Giants Player Salary, Oukaning Ceiling Fan Installation Instructions, Blairmount Public School Principal Stood Down, Port Protection, Gary Muehlberger Dog, Articles P