This video is meant to be used in combination with the printed instructions that accompany your Ridge. To use this calculator, first find the total square footage of the attic floor area. We did a complete tear off and replacement of the roof deck, installed The Edge Vent (roof top intake) and ShingleVent II ridge vent (exhaust).Rich Rogge, Owner, Rogge Builders, Inc. Editors Note:Mixing types of attic exhaust vents on the same roof above a common attic short-circuits the airflow (causes inefficient airflow) because one of the types of exhaust becomes the primary source of intake airflow bypassing (short-circuiting) the actual intake vents. Easily sync your passwords, favorites, and settings across many devices. It is critical to follow all safety precautions while working on the roof, because it is an inherently dangerous job. Its 9 square inches of Net Free Area per linear foot . Then, install ridge vents along the peak of the roof. A drip edge vent inserts intake into the traditional roofing materials. 6) Install starter shingles and then shingle-over the vent. For V-300, use the Folded End Cap technique shown on back page. The homeowner is an engineer and is well aware of the fact that adequate intake is just as important as exhaust. Finish by sealing all seams and nails with roofing cement. Its always best to have one type of attic exhaust combined with the necessary intake ventilation low on the roof or in the soffit. First, run a narrow strip of self-adhering membrane over the top of the fascia and onto the roof deck. 1. . Boost your browsing experience with world class performance and speed, optimized to work best with Windows. The DryerWallVent now also includes a drip edge for even more help. Bone Dry Roofing proposed ShingleVent II ridge vent for one attic that had a generous ridge length (25 linear feet) and a 30-watt solar powered fan for the 2nd attic (it only had 4 linear feet of ridge length available so a ridge vent would not work). We use cookies to ensure you to get the best experience on our website. Getting Insurance to Pay for Proper Attic Ventilation, Ventilation Installation Professional Program. Our crew had installed The Edge Vent before so we were familiar with the installation. Everyone should have access to the best technology and information available, which is why we strive to provide a comprehensive resource for all things browser-related. The ridge vent should be placed on the highest part of the roof, and the intake vent should be placed on the lowest part. Measure 3/4" further up to mark upper slot line. Cut out the area for the airflow slot. Each one has its perks and downsides and different conde limitations and regulations. Edge Vent Installation Steps 1. As you might expect, installation is quite complicated. When we inspected this roof it was clear the shingles were blistering badly and cracking. Headquarters: 127 E County Rd C. #3, St. Paul, MN 55117 Photo 3: Rectangular undereave vents added See CertainTeed's Roofing Ventilation Products Limited Warranty document for specific warranty details regarding this product. I decided on vented drip edge over soffit vents because of ease of installation. As part of a full siding project for this house, we blocked off the gable louver so it would not short-circuit with the ridge vent and we installed fully vented soffit where there were overhangs.Michael Scaperato, Owner, 3rd Generation Home Improvements. Available in 12 ft. length Aluminum soffit 0.019" thickness NFA Rating: 11.0 Q800 TuffTech finish Texas has brutal summers. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. Roof vents should be installed after the shingles are in place. 5. Patented internal baffles and drainage system along with an internal weather filter provide three levels of weather protection. Even in the worst of situations with ice damming we have never had problems. A continuous soffit vent runs about $3-5 per sq.ft. Photo 1: Edge Vent slot cut.Photo 2: Water-protective membrane will be installed under the vent and again over the vent.Photo 3: Making solid progress.Photo 4: Completely installed. 5) Install the 2nd layer of water-protective membrane over the vent. Easily sync your passwords, favorites, and settings across many devices. The house had blind soffits and was not vented at the eave. Excess energy is converted into exhaust as a result of any excess intake from the outside of the house. It's your perfect solution for intake venting on homes with little or no soffit area. Drip edge vents, like fascia vents, are helpful for roofs that cannot use enough soffit . Step 1 - Remove all roofing materials for reroof applications. It can be used to supplement existing soffit or undereave vents as well. As soon as you determine that the roof needs more ventilation, youll want a vent or combination of vents with adequate net free space (NFA) for ventilation. Roofs Over Georgia, Canton, GAAddress: 915 Goodwin RoadCanton, GA 30114Phone: 866-677-0347Web: https://www.roofsovergeorgia.com, Using The Edge Vent with two Air Vent Power Cool Plus 15 roof-mount power fans reduced the air temperature inside the attic dramatically. Download Microsoft Edge as your new trusted web browser today. Cleveland Remodelers, Inc., Novelty, OHAddress: 13694 Northwood Road, Novelty, OH 44072Phone: 440-338-1200Email: markd@clevelandremodelers.com. Each 4-foot piece has an integrated end plug on both ends to provide a finished appearance and weather protection. Air Vent, the industry leader in residential attic ventilation has ashingle-over, edge-of-roof installed intake vent The EdgeVent. Then, remove as much lint as possible by hand. This will show the nailing line at 2.5" up from the lift edge of the US RoofVent. Note: because today's tighter homes require more airflow, the 1/150 ratio is also included. It is recommended that edge flashing be used underneath The Edge Vent to conceal the roof deck-fascia board intersection. A new Windows experience, bringing you closer to the people and things you love. Cut 3/4" slot opening starting 5 inches from the roof's edge. He is also looking forward to the LP truck driving past his house and not stopping to fill his tank every 2 to 3 weeks because he was out of LP. Flashing refers to thin pieces of impervious material installed to prevent the passage of water into a structure from a joint or as part of a weather resistant barrier system. 4. For new home construction that includes a vapor retarder, the minimum is 1 square foot of ventilation for every 300 square feet of attic floor space. Hello all, I am new to this forum. Builders Edge Install Guide. Sync your passwords, favorites, and collections, across your signed-in devices. The attic temperature was only 10 degrees hotter than the upstairs bedrooms and only 12 degrees hotter than the 97 degrees outside. Sync your passwords, favorites, and collections, across your signed-in devices. If you dont already have one, installing one on a roof with shingles is a fairly simple job. vents can be added to both gabled and flat roofs, and there are a variety of different types to choose from. Edge Vent Installation Steps (Note: Complete step-by-step installation instructions are included inside the product carton and can also be found on www.airvent.com) 1. The homeowner is thrilled and raved about the change. Jim Witter, Owner, J & M Contracting, Monarch Siding & Windows, Inc., Papillion, NEAddress: 308 E. Cary Street, Papillion, NE 68046Phone: 402-596-1414Email: tom@monarchsiding.comWeb: https://www.monarchsiding.com/. A. If there is a change in ownership, the warranty may be transferred by the original purchaser of the product to the new owner (first subsequent owner) under the terms and conditions of this warranty. Microsoft Edge: A Web Browser For Everyone, How To Adjust The Volume Of Microsoft Edge, Microsofts Plan To Make Edge The Default Browser Backfires, How To Change The Default PDF Viewer In Outlook, How To Fix Microsoft Edge If Its Not Displaying Your Email, Why Is Microsoft Edge Taking So Much Network. In a quick review of the Leaf Proof gutter protection product, Air Vent does not believe that The Edge Vent will work without significant customization of the installation. Install edge flashing and gutter straps as necessary. Keeping your attic well-ventilated may even reduce your energy costs.*. The Roofing Company of Burlington, IncAddress: 29208 Plank Rd., Burlington, WI 53105Phone: 262-534-6005Fax: 262-534-6007Web: https://www.trcob.com, The 100+ year-old church, now our local Historical Society, needed a new roof. Ridge vents should be cut only to the edge, but vent caps can be installed all the way to the edge. Utilizing Air Vent products and technology we devised a solution resulting in a balanced ventilation system. ShingleVent II ridge vent combines beauty and performance with its low-profile design and proven airflow & weather protection resultsview more. Chuck Power from Square Deal Building Supply in Sterling Heights, MI shares his insight from a recent installation of The Edge Vent intake ventview more. ProductsAbout usNews & EventsResourcesInstallationFAQsSupportContractors & Professionals, Exhaust VentsSolar Attic FansIntake VentsWhole House FansBath or Dryer VentsSkylight TubesWhere to BuyAsk the ExpertTM, Air Vent | 4117 Pinnacle Point Drive, Suite 400 | Dallas | TX | 75211 | 800.247.8368 (800-AIR-VENT), Gibraltar Acquires QAP, Expands Building Products Capabilities. We positioned The Edge Vent more than halfway up the roof where the second-floor attic started. We knew there had to be a way to properly ventilate the house while allowing the customer to maintain the manufacturers shingle warranty. using 1 1/4" x 3/8" min. The vent shall be capable of installation in various climate zones through the US and Canada The vent shall be constructed with a minimum of (10) pre-formed nail bosses for positioning the vent on the roof prior to shingling . Aug 23, 2011 (Edited) About three years ago I had a new roof installed with ridge vent and vented drip edge. Air Vents Intake Vent: The Edge Vent provides proper intake ventilation for homes with little or no overhang. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries and regions. The intake system must provide as much as or more than the exhaust system in Net Free Area. Our evaluation of the attic ventilation showed the homeowners they had no intake. It is not necessary to remove the shingles before marking the outline, and some builders do so. 3. Viewer alert: Keep an eye out for climate-appropriate underlayment under and over the vent. Copyright 2022 Air Vent, Inc. All Rights Reserved. The average ridge vent price is about $2 to $3 per linear foot. Making matters worse, the opening for the soffit vent (intake) was never cut which means it did not have any intake. Additionally, no intake ventilation was present on the front of the house. Microsoft Edge is the fast and secure browser that helps you protect your data and save time and money. Edge vents are installed on the edge of the roof, and they allow air to flow under the roof, helping to keep the temperature inside the house consistent and preventing the formation of ice dams. Attic Soffit Vents & Baffles. Color: Black. Measure 5" from edge flashing bend to mark lower slot line. The dimensions of the NFA are typically square inches, whereas the dimensions of the attic are square feet. To make matters worse, the lack of ventilation was causing the 10-year-old shingles to fail. Unfortunately I made a mistake of not thinking it through or consulting with pros. The big advantage is that the roof edge vent not only provides permanent intake airflow, but also simplifies vent installation, by . Low profile, efficient ventilation will help to keep the attic temperature in check all year. Mike Lunsford, Owner, Lunsford Construction, Inc. Editors Note:: The gable louver visible in the picture has been blocked from inside the attic to avoid possible short-circuiting of the exhaust vents (which can happen when 2 different types of attic exhaust vents are used on the same roof above a common attic). This is what sets us apart. Before cutting the existing vent, measure the dimensions (diameter of the opening) of the existing holes. 1.800.643.5596 Lomanco, Inc. lomanco.com . Set 4 nails 1/2"from ends and 2" up from edge on each corner of vent, add 2 nails in center of vent 2" up from edge. The architecture of the house did not allow for The Edge Vent to be installed at the eve of the roof. In terms of structural integrity, The Edge Vent will perform similarly to Air Vents ShingleVent II ridge vent, which is the same exact copolymer resin material as The Edge Vent. Unlike plastics which fade and crack and lightweight metal that easily crushes, this is one vent you can count on for the long haul. This may not work for all roofs. By using this website, you agree to our use of cookies. In this case, Arrington Roofing has positioned The Edge Vent further up the roof and its working. In other words, its a question of what is your opinion. Note: Calculations are based on ShingleVent II and Multi-Pitch FilterVent which provide 18" of net free area per linear foot. The job turned out great and the vents worked great. Chris Schmider, VP of Operations, Prescott Roofing, When we inspected this gambrel roof and attic we found multiple exhaust vents in use; power fan, ridge vent and gable vents. Image 1)Edge Vent slot cut near valleyImage 2)Edge Vent installed with guttersImage 3)ShingleVent II and Edge Vent Installed, Square Deal Building SupplyAddress: 7670 Nineteen Mile Rd.Sterling Heights, MI 48314Phone: 586-731-3670. We also installed ShingleVent II ridge vent to balance the attic ventilation system. Builders Edge 8.25 In. All of the work is done on the roof which saves us time and money. Chuck Power, Square Deal Building Supply. Remove the template and cut the hole. Many homes in south Irving, TX area have no overhang. More than ever we are finding opportunities to use this product. Eion Kelley, Owner, Northeast Contracting Corporation. Limited Lifetime Warranty and 5-year Replacement Plus Protection. Deck-Air Intake Vent: Roof Edge and Off Roof Edge Install: 300 Series: Gable Vent: A Style: BRV34: BATH PRO: Roof Jack for 3" & 4" Exhaust Fans: BRV34KIT: BATH PRO KIT: Packaged Kit for BRV34 Roof Jack: KV68: KITCHEN PRO: Roof Jack for 6"-8" & 3-1/4" x 10" Exhaust Fans: Product, installation and comparison video resource. 1. A bottom-intake design that helps protect against wind-driven rain up to 110 MPH. -When installing any type of roof vent, be sure to use roofing nails or screws that are specifically designed for the material of your roof. Cleveland Remodelers learned about the above project because of a referral from a satisfied customer across the street. Low profile ShingleVent II ridge vent blends in beautifully with the roof while providing non-stop,continuous exhaust airflow for the attic along the entire peak of the roof. Together they help remove any built-up heat and moisture inside the attic for year-round ventilation. Elite Exteriors balanced the attic ventilation system by replacing the roof louvers with Air Vents ShingleVent II ridge vent for exhaust and added The Edge Vent for intake. 2. 3. Pre-fasten final section. thickness of shingles. Drip edge vents are a two-in-one installation that promote water shedding at the eaves and rakes of a roof, while also allowing for ventilation into the attic. Builders Edge Brochure. Builders Edge offers vinyl siding roof ventilation that's low maintenance, easy to install, and achieves a polished look to fit any architectural style. Prepare the back of the gable vent and installation surface but cleaning free of debris. Our team came together in an extraordinary way over the last several months and created a new level of community, culture and family. Copyright 2022 Air Vent, Inc. All Rights Reserved. THE SIMPLE MATHEMATICS OF A BALANCED RIDGE VENTILATION SYSTEM. Fan capacities in the $300 to $400 range can reach up to 5,000 CFM. Cut the strips of material to size. Sometimes residential roofing contractors reach out for assistance with educating homeowners about the importance of attic ventilation. An industry leader has recently developed an edge-of-roof installed intake vent, known as The Edge Vent. Note the air slot is kept away from both the valley and end of eave. Image 1)Edge Vent Up the RoofImage 2)House in ProgressImage 3)House Built in 1850sImage 4)Hip Ridge Vent, JSD Sanchez Roofing, OKAddress: 1340 SW Straka TerraceOklahoma City, OK 73159Phone: 405-210-8632, By our estimation, the shingles were less than 10 years old but were already sunbaked due to inadequate attic ventilation. When shingles are lapped over the end of product and onto ridge, there is no need for an end cap. We used vented nail base with The Edge Vent to provide intake ventilation. For example, they may use the wrong nails when securing the ridge vent or cut open the entire ridge air slot below the vent. When pressing the vent up against the wall, some adhesive caulk will seep out. Roofing contractors share how they solved challenging roofs and attics that needed proper ventilation. Photo 4: Installing ShingleVent II ridge vent There are no overhangs. And its not noticeable after installation. Even with a small amount of snow on the roof it now melts evenly. Geremiah Gilliand, President, G & G Restoration. gable vinyl rectangle vent builders edge lowes 3. Lack of proper airflow contributed to this. Photo 1: Before: Gable louver on the side of the house is an exhaust vent (but it will be removed) Repeat this step at the other end of the ridge. It can be used to supplement existing soffit or undereave vents as well. 3 Editors Notes: By relying exclusively on ShingleVent II ridge vent for exhaust ventilation and eliminating the roof louvers and gable louvers Buck Roofing & Construction addressed the potential weather infiltration and inefficient airflow performance that can result when two types of exhaust vents are mixed on the same roof (known as short-circuiting). Almost all roofing companies are very familiar with ridge vent installation. We installed The Edge Vent (for intake) and ShingleVent II (for exhaust). Buy Now!New Vapor Canister Vent Valve from 1AAuto.com http://1aau.to/ia/1AZMX00094In this video, 1A Auto shows how to remove, install, and replace the vapor . These low profile window deflectors help to reduce wind noise and allow interior heat to escape. Editors Notes: Strander Roofing & Seamless Gutters installed 2 layers of 3-inch insulation (R-Value of 42) and applied fir strips over the top of the insulation; then installed the sheeting to the fir strips. It's a roof-top installed,. Find inspiration for your creative projects, with features designed to personalize your experience for work and play. Our Project Manager Jake Geisler evaluated the roof and worked closely with the local Air Vent representative Bill Pierro to specify The Edge Vent for this house that did not have an overhang for traditional intake vents. Jason Vogen, CEO, Elite Exteriors. We use cookies to provide you with a great experience and to help our website run effectively. And experts should only carry out the installation. Instead of sending another crew to install soffit vents. The install process involves using a saw to cut a 2 inch wide gap along the entire peak of the roof. Getting Insurance to Pay for Proper Attic Ventilation, Ventilation Installation Professional Program. The customer is very happy with the finished product and is very appreciative that we were able to bring their attic ventilation up to code. Judd Haag, General Manager, Bone Dry Roofing, BTR Construction & Roofing, Matthews, NCAddress: 600 West Charles Street, Suite AMatthews, NC 28105Phone: 704-363-6895Email: kevin@btrroofing.comWebsite: www.btrroofing.com, We really enjoy using The Edge Vent on our reroof projects that do not have enough intake or any intake. LICENSE INFO: Blue Ox Exteriors is an Owens Corning Platinum Preferred contractor, less than 1% of contractors nationally have this certification. 2 Fig. Sync your passwords, favorites, and settings across multiple devices and start using Microsoft Edge today. Here's an overview of the specifications for Air Vent's complete line of intake ridge ventilation products. Position The Edge Vent over the slot. It was extremely hot in the summer and very cold in the winter. The deep-draw manufacturing process ensures a clean exterior that looks . However, if this is not the case for you, be sure to call in the professionals for this job. They are usually used as exhaust vents, however, if the vent is installed on the edge of the roof, it can act as an intake vent. SmartVent is a tapered, under shingle plastic product designed for installation along the soffit edge of the roof or the facing edge of dormer roof to wall and goes virtually unnoticed. Builders Edge gable vents provide added architectural detail with their wood grain finish and sharp distinctive characteristics. 32.625-in x 22.625-in Black Rectangle Vinyl Gable Vent. Drip edge vents are vents installed on the drip edge of the roof. Pre-fasten final section. A good rule of thumb is to place one between each set of rafter tails in order to maximize intake air. That drill into the drip edge itself or added as an add-on to the drip edge. If you decline the use of cookies, this website may not function as expected. We were called by the air-conditioning contractor to ventilate the attic. Prescott Roofing & Remodeling, Inc., Carnegie, PAAddress: 20 W. Noblestown RoadCarnegie, PA 15106Phone: 412-276-4242Website: www.prescottroofing.com, For this church project we installed CertainTeeds Symphony Slate shingles. Chris Arrington, vice president, Arrington Roofing Company, Inc. Editors Note:The attic temperature reading of 114F on a day with outdoor temps at 105F is within the recommended summertime range for a properly performing attic ventilation system: within 10-15 of the outside temperature; 20 max. Sync your passwords, favorites, and collections, across your signed-in devices. for pricing and availability. Proper vent chutes should be installed before blown-in insulation to prevent choking your intake system. Edge vents are installed on the edge of the roof, and they allow air to flow under the roof, helping to keep the temperature . Whatever the mistake, improperly installing ridge vents can cause several problems in your home. Williams Construction, Beach Island, SCAddress: 1457 Augusta RoadBeach Island, SC 29842Phone: 803-594-0900Email: twilliams29803@bellsouth.netWebsite: www.roofingbywilliams.com, The Edge Vent installs great, looks exceptional, and the homeowners report reads that they were very satisfied with the product. Home Restorations, Mechanicsville, MDAddress: 39099 Pond View LaneMechanicsville, MD 20659Phone: 301-472-4119Web: https://www.homerestorations.com. Press the vent up against the wall. It can be used on roofs with minimum 3/12 pitch. To date, we have had zero issues with this and the customer has referred us numerous times since we were able to think out of the box to solve the intake ventilation problem without re-doing the entire soffit area. Jake Gast, Owner, Paragon Exteriors, LLC. Be sure to use factory end on the edge and the cut towards the inside. App Store is a service mark of Apple Inc. Microsoft Edge is available to download on your iOS device. NOTE: Be sure the factory cut end of the vent (built-in end plug) is facing out. Find My Store. 8). We use cookies to ensure you to get the best experience on our website. For all other applications, however, The Edge Vent is intended to be positioned at the very edge of the roof. Patriot Construction, Scottsville, NYAddress: 32 Main Street, Suite B, Scottsville, NY 14546Phone: 585-720-0990Web: https://www.nypatriot.com/. This is because the shingles will help to protect the vents from the elements and extend their lifespan. No field representative of Air Vent or any distributor or dealer is authorized to make any change or modifications to this warranty. Installation Instructions 1. We were very satisfied with the product and feel it looks perfect! on ridge and nail, keeping end of vent 1/2"from end of roof. Allow a 2" opening at Ridge for ventilation. 2. Deck Opening Measure up 6 " from the eave edge, along the rake edge towards the ridge and place a mark on the roof deck (reminder that insulation cannot block the vent opening). Tools used to analyze the data to measure the effectiveness of a website and to understand how it works. In 4-short minutes Bill details many of the key installation steps. If Air Vent replaces any product under this warranty, it may substitute products designated by Air Vent to be of comparable quality or price range in the event the product initially installed has been discontinued or modified. Microsoft Edge for Android Microsoft Edge is available to download on your Android device. This warranty does not cover any labor costs, including those required for field repair or replacement or removal of any allegedly defective part. Editors Notes: Calkins Construction used ShingleVent II ridge vent for exhaust and then balanced the attic system with The Edge Vent for intake. The length of the warranty varies by product. There is no other way to achieve this much intake on a reroof project. Kevin McHugh, BTR Construction & Roofing, Buck Roofing & Construction, LLC, Kansas City, KSAddress: Address: 1122 Merriam LaneKansas City, KS 66103Phone: 913-384-2680Email: rob@rbuckroofing.comWebsite: www.rbuckroofing.com, For this project we replaced the roof louvers and gable louvers with ShingleVent II ridge vent for exhaust and replaced the mini-louvers with The Edge Vent for intake. Below are highlights of the warranty for CertainTeed Ridge Vent. Calkins Construction, Inc., Waynesburg, OHAddress: 7000 Indian Run, Waynesburg, OH 44688Phone: 330-866-5450Email: dougcalkins@aol.com, We used The Edge Vent on the last home we shingled. The shingles were removed and damaged plywood was replaced. The browser that makes it simple to browse your way. Inductive Automations Ignition Edge Is Compatible With Its Ignition Server, The Microsoft Edge Virus: What It Is And How To Remove It. Under this warranty feature, Air Vent, at no charge, will replace any product found to be defective during the Replacement Plus period as long as proof of purchase is submitted to Air Vent (Replacement Plus period begins when the product installation is completed). After adding a new vent cavity to the entire roof system, we were able to ventilate the entire roof deck and turn the attic space into semi-conditioned air space. The Roofing Company, Burlington, WI. We are looking forward to installing more of The Edge Vent in the near future. Chris Williams, Owner, Williams Construction, WM. The positioning adhensive on most profiles with hold ProfileVent in position for easy installation. Here's a step-by-step guide on how to install them: 1. Upon inspection Bone Dry Roofing learned the current pitched roof was built over the top of an existing flat roof. Editors Notes: Tom attended Air Vents Ask the Expert educational seminar 1st quarter 2010 in Omaha and credits the seminar with further enhancing his attic ventilation sales presentation skills. The inner cut does not have to be perfect as the vent will hide much of this area. Photo 2: Adding rectangular undereave vents It had to be installed above the dormers on the front of the house which is close to the floor of the attic. A roof edge vent also provide weather protection and allows for increased airflow due to the radius design. In some cases, when the attic is located on low-pitch roofs, it may require additional ventilation, which benefits the house. Start by disconnecting any existing ducting from the dryer exhaust outlet and the wall. . TruVent is the perfect expression of that idea. As is the case with many of the houses in this area, this house did not have enough intake and the attic was not breathing. Microsoft Edge is available to download on your Android device. Editors Note:Attic ventilation can look beautiful. Microsoft Edge is available on supported versions of Windows, Linux, macOS, iOS, and Android. They are already cutting the slot for the ridge vent. insert connector end plug on each end. Apply a 1/2" bead of wood glue all the way around the back edge of the vent. The homeowner was also very pleased with the appearance. Download for Linux (.deb) | Linux (.rpm). Using The Edge Vent was the best solution. Find information, get specs, download warranties and view install instructions for our most popular Builders Edge products. Color Program. In no event shall Air Vent be liable for consequential or incidental damages of any kind, including any damage to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein, unless exclusion of these types of damages are specifically prohibited by state law. We used a 6-in. SUCCESS STORY - The Edge Vent and ShingleVent II, Arrington Roofing Company, Inc.Address:2203 Obenchain StreetDallas, TX 75208Phone:214-698-8443Website:www.arringtonroofing.com.